How to measure the reflector temperature?

Temperature measurement of ref1

For the use of cob, we need confirm the operating power, heat dissipation conditions and PCB temperature to ensure the normal operation of cob. When using the reflector, we also need to consider the operating power, heat dissipation conditions and reflector temperature to ensure the normal operation of the reflecor. How do we operate the temperature measurement of reflector?

1. Reflector Drilling

Temperature measurement of ref2

Drill the reflector with a circular hole about 1mm in size. The position of the hole shall be at the bottom of the reflector and close to the COB.

2. Fixed Thermocouple

Temperature measurement of ref3

Take out the thermocouple end of the thermometer (K-type), pass it through the circular hole of the reflector, and then fix it with transparent glue so that the thermocouple wire will not move.

3. Painting

Temperature measurement of ref4

Apply white paint on the temperature measuring points of thermocouple wires to improve the measurement accuracy.

4. Temperature Measurement

Temperature measurement of ref5

Generally, connect the thermometer switch to measure and record the data under the condition of sealing and constant current measurement.

How about the temperature resistance of the Shinland reflector?

Shinland optical reflector is made of plasticized materials imported from Japan, with UL_ Hb, V2, UV resistant certification, also meet the requirements of EU RoHS and reach, and the temperature resistance is 120 ℃. In order to break through the temperature resistance of the product, the Shinland reflector has added high temperature resistant materials, just to give customers the best choice.


Post time: Jun-18-2022